Case Report
|
|
Simplified diagnostic-surgical stent for accuracy of implant placement and parallelism
|
Abdul Habeeb Bin Mohsin1,
Husna Khan2,
Mohd. Aijaz Ahmed3,
M. Mahesh Kumar4,
Sarah Samee5
|
1MDS, Assistant Professor, Department of Prosthodontics, Sri Sai College of Dental Surgery, Vikarabad, India.
2BDS, Dental Surgeon, Mahavir Dental Hospital, Hyderabad, India.
3(MDS), Post Graduate Student, Department of Periodontics, Government Dental College, Vijayawada, India.
4(MDS), Post Graduate Student, Department of Periodontics, Sri Sai College of Dental Surgery, Vikarabad, India.
5BDS, Dental Surgeon, BMS Dental Hospital, Hyderabad, India.
|
Article ID: 100023CRINTAM2016
doi:10.5348/crint-2016-23-CR-4
|
Address correspondence to:
Dr. Abdul Habeeb Bin Mohsin
23-2-360/3 Moghal Pura
Hyderabad 500002
Telangana
India
|
Access full text article on other devices
|
|
Access PDF of article on other devices
|
|
|
[HTML Full Text]
[PDF Full Text]
[Print This Article]
[Similar article in Pumed]
[Similar article in Google Scholar]
|
How to cite this article:
|
Mohsin AHB, Khan H, Ahmed MA, Kumar MM, Samee S. Simplified diagnostic-surgical stent for accuracy of implant placement and parallelism. Case Rep Int 2016;5:13–17.
|
|
Introduction:
This article describes a method of evaluation of available alveolar bone dimensions and guided implant placement in a patient with the fabrication of diagnostic-surgical implant template.
Case Report:
We present a case of 37-year-old female patient with a missing tooth to be replaced with dental implant using guiding template. The diagnostic template was transformed into a surgical template for implant surgery. The method described is simple, enabling the practitioner to perform radiographic diagnosis and placing the implant precisely using surgical template. This helps in treatment planning and to assess available alveolar bone at the site of planned implant insertion.
Conclusion:
This method is easy to follow; significant time and cost savings can therefore be realized by using this template to perform dental implant osteotomy. It provides adequate accuracy in terms of implant position, angulation and predictable treatment outcome.
|
Keywords:
Implant, Imaging, Position, Stent
|
[HTML Full Text]
[PDF Full Text]
|
|
Author Contributions
Abdul Habeeb Bin Mohsin – Conception and design, Acquisition of data, Analysis of data, Drafting the article, Critical revision of the article, Final approval of the version to be published
Husna Khan – Conception and design, Drafting the article, Final approval of the version to be published
Mohd. Aijaz Ahmed – Conception and design, Acquisition of data, Analysis of data, Drafting the article, Final approval of the version to be published
M. Mahesh Kumar – Conception and design, Acquisition of data, Critical revision of the article, Final approval of the version to be published
Sarah Samee – Acquisition of data, Analysis and interpretation of data, Drafting the article, Critical revision of the article, Final approval of the version to be published
|
Guarantor of submission
The corresponding author is the guarantor of submission.
|
Source of support
None
|
Conflict of interest
Authors declare no conflict of interest.
|
Copyright
©
2016 Abdul Habeeb Bin Mohsin et al. This article is distributed under the terms of Creative Commons Attribution License which permits unrestricted use, distribution and reproduction in any medium provided the original author(s) and original publisher are properly credited. Please see the copyright policy on the journal website for more information.
|
|
|